Matching works

1 work

math.ST — Statistics Theory

Separate fits and joint compatibility in heterogeneous coverage: finite-label models with shared calibration

Contributed by HUANG Man

Two preparation experiments can each fit a heterogeneous coverage model and still fail a shared-environment explanation. We characterize joint compatibility for finite-label probability representations with half-step source probes and pointwise calibration error. Absolute weaker-source void probabilities require the weighted calibration marginals to share mass at least κ=(β1+β2−1)+\kappa=(\beta_1+\beta_2-1)_+. Combining this observed budget with exposure moments and a shared calibration band gives an exact criterion for the closure of the representation. A deterministic-anchor example requires error radius 0.103760.10376 for separate fits and 0.330480.33048 for joint compatibility. On an explicit three-moment family, matching bounds identify the first-order heterogeneous coefficient κ\sqrt\kappa; four environments preserve the anchors and give second-order stability of the minimum radius over unknown centers. A calibration-preserving moment repair and response-opening geometry yield sharp local inverse bounds with unknown, unequal group masses and first anchors. For prescribed mass and standard-deviation envelopes pn,hnp_n,h_n with hn2≤bpnh_n^2\le bp_n, the matching radius-estimation risk is min⁡{1,[n−1/2+min⁡(hn,n−1/4)]/pn}\min\{1,[n^{-1/2}+\min(h_n,n^{-1/4})]/p_n\}. Uniform consistency has a corresponding two-scale necessary and sufficient criterion. Unknown envelopes introduce distinct adaptation costs. An interval honest over the full envelope union has matching expected diameter min⁡{1,n−1/4/pn}\min\{1,n^{-1/4}/p_n\} even on the deterministic subclass. Under uniform protection of the deterministic regular risk, point estimators pay a sharp logarithmic cost elsewhere: one scale-free thresholded projection attains min⁡{1,[n−1/2+min⁡(hn,(log⁡(en)/n)1/4)]/pn}\min\{1,[n^{-1/2}+\min(h_n,(\log(en)/n)^{1/4})]/p_n\}, and a constrained-risk lower bound matches it. The larger mass-unrestricted moment class admits no uniformly consistent radius estimator. Simultaneous Bernoulli confidence events also give finite-sample compatibility certificates.

Author comments: Published English–Chinese preprint: https://doi.org/10.5281/zenodo.24412395. Joint compatibility, calibration-radius stability and inference for heterogeneous finite-label coverage with shared calibration. Companion preprints: doi:10.5281/zenodo.23912425 and doi:10.5281/zenodo.23911961. Reproducibility scripts and synthetic fixtures are included under anc/.

A mix of human-written and AI-generated textHuman understanding: some partsfinite-sample testingheterogeneous mixturesoverlapping measurespartial identificationshared calibrationtruncated moment problem
Nov 21, 202653 pages
PDFView work

Advanced search

Text
Human understanding
Linked formalizations